Models |
HT-20KVPac |
HT10000PAC |
HT-10kac-500mA |
HT-5000PAC-200mA |
HT-3000PAC-1A |
HT-2000PR |
HT-2000S |
HT-2000P |
Voltage Test Type |
AC |
AC |
AC |
AC |
AC |
AC |
AC/DC |
AC/DC |
Maximum Output Voltage |
0 - 20,000 Vac |
0 - 10,000VAC |
0-10kV AC into High Voltage jack/receptacle with 4 foot lead and alligator clip. |
5000V |
3000V |
2000V/2800V |
2000VAC/2800VDC |
2000VAC/2800VDC |
Maximum Leakage Current |
5mA from 0 to 20,000V |
0 - 8000V=10mA, 10000V=8mA |
User adjustable by front panel knob 25-500 mA |
5.0mA to 200mA in 1mA steps |
1000mA |
20mA/5mA |
20mA/5mA |
20mA/5mA |
Input Voltage |
120 V *optional different line voltages available (100V, 110V, 220V, 230V, 240V) |
120 V *optional different line voltages available (100V, 110V, 220V, 230V, 240V) |
230V |
120VAC |
240VAC |
120VAC |
120VAC |
120VAC |
Frequency |
50/60 Hz |
60Hz |
50/60Hz |
60Hz |
60Hz |
60Hz |
60Hz |
60Hz |
Fuse |
120/230 VAC 2A/1A Slow Blow |
120/230 VAC 2 A Slow Blow |
30A |
120/230 VAC 2A/1A Slow Blow |
- |
120/230 VAC 2 A Slow Blow |
120/230 VAC 2 A Slow Blow |
250 VAC 2 A Slow Blow |
Breakdown Detect |
Independent High Frequency Circuit |
Independent High Frequency Circuit |
- |
Independent High Frequency Circuit(50KHz-500KHz) |
Independent High Frequency CircuitLow sensitivity spark with high energy detected to prevent damage. |
Independent High Frequency Circuit(50KHz-500KHz) |
Independent High Frequency Circuit(50KHz-500KHz) |
Independent High Frequency Circui |
Transformer Power |
< 500 VAC |
< 500 VAC |
- |
>500VA |
>500VA |
>500VA |
>500VA |
< 500 VAC |
Leakage Current Detect |
Independent Low Frequency Circuit |
Independent Low Frequency Circuit |
500 mA maximum (continuous duty) |
Independent Low Frequency Circuit |
Independent Low Frequency Circuit |
Independent Low Frequency Circuit |
Independent Low Frequency Circuit |
Independent Low Frequency Circuit |
Ramp Time Range |
1 - 5 seconds |
1 - 5 Seconds |
Manual ramp only. |
- |
- |
1 - 5 Seconds |
1 - 5 Seconds |
1 - 5 Seconds |
Test Time Range |
1 - 60 seconds |
1 - 60 seconds |
User adjustable 1-60 sec. or defeat (desired voltage delivered while TEST button is pressed). Continuous on is optional (Option 00-RF). |
1 - 60 seconds |
1-60 seconds or defeat (desired voltage delivered while TEST button is pressed). Continuous on is optional (Option 00-RF). |
1 - 60 seconds |
1 - 60 seconds |
1 - 60 seconds |
Discharge Timer |
<7ms |
- |
Voltage dependent; discharge progress displayed on front panel meter. |
<7ms |
- |
<7mS For AC<1.35 For MAX DC at open circuit |
<7mS For AC<1.35 For MAX DC at open circuit |
<7mS For AC<1.35 For MAX DC at open circuit |
Display |
4 Digits LED Display |
4 Digits LED Display |
4 Digits LED Display |
4 Digits LED Display |
4 Digits LED Display |
4 Digits LED Display |
4 Digits LED Display |
4 Digits LED Display |
Voltage Meter Accuracy |
± 0.1KV Full Scale |
± 2 % |
± 3% 500 - 10000V, Current ±4% 5mA-500mA |
± 2 % from 500Vto 5000V |
± 2 % +/-1 count |
± 2 % |
± 2 % |
± 2 % from 500-2000 volts AC± 2 % from 500-2800 volts DC |
Leakage Current Accuracy |
± 0.1mA Full Scale |
± 0.1 mA Full Scale |
- |
± 0.1 mA Full Scale |
± 2 % +/-1 count |
± 0.1 mA Full Scale |
± 0.1 mA Full Scale |
± 0.1 mA from 1 – 17mA AC± 0.1 mA from 1 – 5mA DC± 0.2 mA from 17 – 20mA AC |
Duty Cycle |
100% |
100% |
100% |
100% |
100% |
100% |
100% |
100% |
Operation Temperature |
15-40 °C |
15-40 °C |
15-40˚C |
15-40˚C |
15-40˚C |
15-40˚C |
15-40˚C |
15-40˚C |
Relative Humidity Range |
0-90 % Non-Condensing |
0-90 % Non-Condensing |
0-90% non-condensing |
0-90% non-condensing |
0-90 % Non-Condensing |
0-90 % Non-Condensing |
0-90 % Non-Condensing |
0-90 % Non-Condensing |