Not seeing a Scroll to Top Button? Go to our FAQ page for more info.
flow meter instrument manufacturer Rajkot Convert and Communicate Instruments manufacturer Rajkot rubber testing equipment vendors in rajkot magnetic particle inspection equipment seller Rajkot
Vision Measuring System vendors in rajkot

TECHNICAL SPECIFICATIONS

Models 240 S Series
240 W DC Euro Cassette Switched Mode Power Supplies
600S Series
600W Switched Mode DC Power Supply
Output Adjustable 12-30V with screwdriver or analog programmable by 2-5V factory set at 24V. 0-6V/0-40A ,0-15V/0-18A,0-28V/0-10A
(For S6-40,S15-18,S28-10 Respectively)
Input AC 195-265V 48-62Hz 1.8Arms
AC 100-132V 48-62Hz 3.2Arms
for DC or operation at 400Hz Contact Factory
fuse 4AT at 230V 6.3AT at 110V
AC 195-265V 48-62Hz 1.8Arms
AC 100-132V 48-62Hz 3.2Arms
for DC or operation at 400Hz Contact Factory
fuse 4AT at 230V 6.3AT at 110V
Safety EN 60950 EN 61010(SELV/PELV) EN 60950 EN 61010)
EMC EN 61204-3 power supply standard
EN 61000-6-3 emission(EN 55022B)
EN 61000-6-2 immunity
EN 61204-3 power supply standard
EN 61000-6-3 emission(EN 55022B)
EN 61000-6-2 immunity
Efficiency 89% at 240W output(max. heat dissipation 36W) 80%,86%,88%(For S6-40,S15-18,S28-10 Respectively)
Ripple +noise(BW=20MHz) 5mV rms.,15mV p-p 5/25mV,15/50mA
Output imp 0.1 Ohm upto 100KHz 0.1 Ohm
Recovery time 200 Us after 50-100% load step 100us 50-100% load step
insulation
input/output 3750Vrms.(1 min.) Harmonic current meets EN 61000-3-2
input case 2500Vrms.(1 min.) Harmonic current meets EN 61000-3-2
output case 500V DC Harmonic current meets EN 61000-3-2
Hold up time 20ms(24V/10A,230 V AC input) 100% Load 220 V AC:20ms
50% Load 220 V AC:40ms
Height 240mm 106mm
Width 71mm 194.5mm
Depth 156mm 166mm
Weight 2.0Kg 2.8Kg