Models |
1200 S Series 1200 W Switched Mode Power Supply |
600S Series 600W Switched Mode DC Power Supply |
Input Voltage |
AC 198-264V ,48-62Hz,8.2 Arms fuse 15AT crest facory 2.2AC 99-132V ,48-62Hz,16.4 Arms fuse 25ATDC Contact Factory |
AC 198-264V ,48-62Hz,3.8 Arms fuse 6.3AT crest facory 2.0AC 99-132V ,48-62Hz,7.6 Arms fuse 12.5ATDC Contact Factory |
Insulation |
Input/Output |
3750V rms(1min) |
3750V rms(1min) |
Input Case |
2750V rms(1min) |
2750V rms(1min) |
Output Case |
500V DC |
500V DC |
Inrush Current |
Limited by 39Ohm (Shorted after startup) |
Limited by 47Ohm (Shorted after startup) |
Line distortion |
Kept low by large low frequency choke input |
Harmonic current meets EN 61000-3-2 |
Power factor |
0.72 at 230 V AC input and full load |
0.76 at 230 V AC input and full load |
Safety |
EN 60950/EN 61010 SELV/PELV(FOR 1200S 24 ONLY) |
EN 60950/EN 61010 SELV/PELV(FOR 1200S 24 ONLY) |
EMC |
EN 61204-3 power supply standardEN 61000-6-3 emission(EN 55022B)EN 61000-6-2 immunity |
EN 61204-3 power supply standardEN 61000-6-3 emission(EN 5522B)EN 61000-6-2 immunity |
VDEO 160 impulse test |
input with stands non periodic impulse 2.3 on 0.3 ms of VDEO160 class1 |
input with stands non periodic impulse 2.3 on 0.3 ms of VDEO160 class2 |
Parallel operation |
For safe parallel operation current limit switch at 'LO'(Max. 1100W) |
No restriction |
Output Voltage |
Scewdriver adjustable with 10 turn potmeter at the at the near side Also programmable by 2-5V |
Scewdriver adjustable with 10 turn potmeter at the at the near side Factory st at 24.0V Also analog programmable by 2-5V |
Efficiency |
89% at 230V AC input |
89% at 230V AC input and 600W output (max. heat dissipation 74W |
Regulation |
Load 0-100%-Better then 10mV Line 198-264-Better then 5mV |
Load 0-100%-Better then 10mV Line 198-264-Better then 5mV |
Ripple +noise |
Max. 7 mV rms 20 mV rms. |
Max. 7 mV rms 20 mV pp(BW=20MHz) |
Output imp |
Less then 0.05 ohm upto 100KHz |
Less then 0.05 ohm upto 100KHz |
Recovery time |
0.3 millisecond to recover within 100mV after 50 to 100% load step max deviation 300mV |
0.3 millisecond to recover within 100mV after 50 to 100% load step max deviation 300mV |
Hold up time |
15 ms at 115 or 230 V AC input and full load 30 ms at half load |
33 ms at 115 or 230 V AC input and full load 60 ms at half load |
Series operation |
Upto 500V total voltage |
Upto 500V total voltage |
Redundant parallel operation |
Schottky diode to seperate the outputs put current limit at 'LO' do not use remote sensing. |
Use R+ connection via build in schotetty diode to seperate the outputs .Do not use remote sensing. |