SALIENT FEATURES

Impulse voltage of 100V-5kV, Eight channel
Individual channel can be program and control
Minimum inductance test value winding:10µH
Up to 200MSa/s waveform sampling rate
Maximum measuring speed: 6meas/sec
Storage depth of 6k Bytes
High bandwidth analog acquisition circuit
High -fidelity corona extraction algorithm
Four waveform comparision methods
Automatic storage of instrument parameters
Measurements on voltage, time and frequency
Amplification,stretch and movement of the waveform for accurate display
Multi sample average, average processing of 32 standard waveform
Use demagnetized impulse to ensure the conformity of tested waveform
20 groups of instrument files storage and retrieval
Screen information storage in USB disk
System firmware up gradation facility through USB-disk
Foot control interface for easy measurements
Handler interface to realize on-line operation
65k color 7" TFT wide display screen
RS232C, USB Device and LAN interface to realize remote control

ORDER SELECTION GUIDE

TECHNICAL SPECIFICATIONS

SME1201-1 SME1205-1 SME1205-4 SME1205-8 SME1210-1
No. of channels 1 1 4 8 1
Output Impulse Voltage 30V-1200V 100V 5000V 500V 0 V
5V steps 10V Steps 20V Steps
Voltage Accuracy ± (5% of set value + 5V) ± (5% of set value + 15V) ± (5% of set value + 25V)
Read back Accuracy ± (5% actual value + 5V) ± (5% actual value +15V) ± (5% actual value + 25V)
Inductance Test Range >=1µH >=10µH >=20µH
Impulse Energy Max : 0.02 Joule >Max : 0.25 Joule >Max : 0.5 Joule
Test Speed 6 meas/ second 6 meas/ second 3 meas/ second(when 10kVimpulse voltage is output)
Pulses Applied Max : 32
Input Impedance 5M Ohm
Waveform Acquisition Sampling Rate Max 200 MSa/s, 8 levels adjustable Resolution 8 Bits Memory Depth 6k Bytes Average : 1 to 32
Comparison Mode Area size comparison,Differential area comparison,Corona discharge comparison, Differential phase comparison
Waveform Measurement Voltage, Time, Frequency
Trigger Mode Internal/ Manual (foot)/ External/ BUS
Detection Output PASS/ FAIL display /LED/Alarm
Measurement Statistics Statistics for Measurement Results
Memory 20 groups of standard waveform data & instrument setup can be stored in internal non-volatile memoryUSB flash memory can be used as external memory
Interface HANDLER, RS232C, USB Device, USB Host, LAN
Gernal Information
Display 800X480 Dots, 65k color TFT, Waveform Display Range : 600x256
Safety and electromagnetic compatibility IEC61010-1:2001, IEC61326-2-1:2005
Supply 220V ± 10 %, 50/60Hz ± 5%
Power consumption =<200VA/td>
Operating Conditions 0°C 40°C, 5% RH
Weight 7.2 kg (Approx.)
Standard Accessories Foot Switch, High-voltage test clip leads, User Manua