Not seeing a Scroll to Top Button? Go to our FAQ page for more info.
industrial instrument in  rajkot Measuring Instruments  in rajkot process control instrument manufacturers in India Metrology Instruments manufacturers in rajkot
industrial instrument in India

Principle

Sapcon Admittance series level switch uses a three element immuno coat technology and uses precision rectifier to eliminate voltage of shield due to build-up of material. The Oscillator generates an AC voltage which drives a current through the capacitance influenced by the product. This AC current is transformed by a precision rectifier in to a DC current which is transmitted to the evaluation instrument and compared with a pre adjusted set value. The shielded electrode is connected to the minus of the AC voltage, therefore in case adhesion, the current flows from the sensitive measuring part to the shielded electrode and not via precision rectifier. Only the capacitance between the sensitive measuring part and container wall cause a current through the precision rectifier.

Features

Ingress Protection of IP-67

Coating Immunity specially for sticky and viscous media

Universal Supply 90-265 V AC and 24 V DC

Available in Integral as well as remote models

Customized Mountings and probe lengths

Available in High temperature even up to 600°C

Mechanical Specifications

Electrical Specifications

Resonant Frequency

Rod Probes:100mm to 3000mm

Rod Probes:600mm to 12000mm

Enclosure

W: Weatherproof

P5: IP-65 Weatherproof and Dust-proof

FA:Flame-proof for Gas Groups IIA and IIB

Versions

Integral Type (Electronics Integral with Probe)

Remote Type (Electronics is separated by 3 core ordinary cable)

Process Connection(Mounting Arrangement)

Threaded Mounting: 1, 1-1/2”, 2” BSP / NPT

Flange Mounting: As per specification

Tri-Clover (as per specifications)

Insulation

PTFE

Ceramic

Probe Length

Extension Length + Fork Length (155mm / 185mm / 250mm)

Wetted Parts and Mounting Material

S4: SS-304

S6: SS-316

SL: SS 316L

Process Temperature

A (Ambient): below 80°C

H1 (High temperature) up to 150°C

H2 (High temperature): up to 250°C

H3 (High temperature): up to 600°C

Input power supply & Outputs

90-265 V AC, 50 Hz

24 V DC

Outputs

01 SPDT relay output

02 SPDT relay output

03 SPDT relay output

Relay with Time Delay Function

PNP output

Pre-amplifier Unit

ICA-3000 for transmission voltage output from Probe to Evaluation unit

Power Consumption

Maximum 5 W

Fail-safe Setting

Field selectable (through toggle switch)

Open: Fail-safe High, Close: Fail-safe Low

Response Time

0.5 – 2 Sec

Time Delay Settings

Cover and Uncover Delay: 0.5 to 20 seconds, field selectable

Sensitivity Setting

Field Selectable (through toggle switches)

Frequency

500 KHz

Applications Specifications

Food Industries & FMCG

Sugar industryl

Food grainsPackaging industry

Foundry & Castings

Soya industry

Bulk material handling

Flour and rice mills

Switching Indication

3 LED’s

Red: Alarm, Green: Normal, Yellow: Healthy Prob