The probe comprises of sense, shield and ground electrodes electrically isolated from the metallic tank by means of suitable insulators. The sense electrodes and the vessel wall serve as the two electrodes of an imperfect capacitor with the service material as the dielectric. A change in material level causes a change in admittance of this imperfect tank capacitors.
Power Consumption: Less than 05 VA
Power Supply: 18 -55 V DC, 90-260 V AC
High temperature durability (Up to 1000°C)
Suitable for very dusty environment
Immune to application material coating on the probe
Self-diagnosis
Rod Probes:200mm – up to 3000mm
Rope Probes:Extend up to 600mm to 12000mm
P5:IP-65 Weatherproof housing
FA:Flame-proof for Gas Groups IIA and IIB
Threaded Mounting: 1-1/2”, 2” BSP/NPT
Flanged Mounting: As per specification
Tri-Clover (as per specifications)
SMS union coupling type
PTFE
Ceramic
Others
S4: SS-304
S6: SS-316
SL: SS 316L
A (Ambient) below 80°C
H1 (High temperature) up to 150°C
H2 (High temperature): up to 250°C
H3 (High temperature): up to 600°C
H4 (High temperature): up to 1000°C with cooling fins
SLA series with electronics insert ICA 3000
Sticky media e.g. slurries, wet sand
Split electronics, sensor – controller distance maximum 1km
SLA..M with Dot Display
Low dielectric media e.g. cement, fly ash, clinkers, ESP hoppers
Remote electronics with 15m distance between probe and controller
SLA..B with Bar Display
Remote Electronics with maximum distance of 50m from the probe
Low dielectric media e.g. cement, fly ash, clinkers, ESP hoppers
Integral type (Electronics integral with probe)
Remote type (Electronic separated by a special cable)
SLA 122/ 120M / 120B: Single SPDT with (90-260 V AC) / 24 V DC
SLA 222 / 220M / 220B: Double SPDT with (90-260 V AC) / 24 V DC
SLA 322 / 320M / 320B: Single SPDT & Time Delay with (90-260 V AC) / 24 V DC
SLA 622 / 620M / 620B: Double SPDT & Time Delay with (90-260 V AC) / 24 V DC
SLA 822: Double SPDT, Time Delay & two channels with (90-260 V AC) / 24 V DC
SLA 922: Three SPDT, Time Delay & three channels with (90-260 V AC) / 24 V DC
Maximum 5 W
Field selectable (through toggle switch)
Open: Fail-safe High, Close: Fail-safe Low
0.5 – 2 Sec
Cover and Uncover Delay: 0.5s to 60s, through potentiometer
Field Selectable (through toggle switches)
100 KHz and 500 KHz
For all Industries requiring level limit detection in Bulk Material Handling
Powders, sand, sugar, Pulverized coal, Food grains
Cement, Stones, Fly-ash, Bed-ash, Clinkers
Granular material
Sticky and hygroscopic materials like honey, paste, cream, syrup, etc.
2 LED’s / Dot / Bar type display
Red: Alarm, Yellow: Sensing, Green: Normal