Principle

Coat-Endure is an improvement over traditional principle of admittance. The 3-element probe has alternating active and inactive regions which help the controller to calculate the extent of coating on probe. In effect, the device is able to identify the relative coating between the sense and the shield by measuring their individual capacitances. As the coating immunity is controlled by the on-board microcontroller, the extent of coating immunity can be set easily.

Features

Suitable for conductive and non-conductive application media

Wide variety of probes – Part-PTFE, Full PTFE, Rope Probe, High Temp. Ceramic Probe

Material independent calibration, Fast installation and commissioning

Immune to fluctuations in process temperature, dielectric constant of the media and variable coating patterns

Universal Power Supply – 18V – 55 V DC , 90 -265 V AC

Mechanical Specifications

Electrical Specifications

Probe Length

Extensible probe length from 65 mm (minimum) to 3500 mm (maximum)

Active Probe Length + Grounding(Extension) + Stand-off length(optional for high temperature)

Enclosure

FC: Flameproof for Gas Group IIc

P5:IP-65 Weatherproof housing

FA:Flame-proof for Gas Groups IIA and IIB

Process Connection(Mounting Arrangement)

Threaded Mounting: 1-1/2”, 2” BSP/NPT

Flanged Mounting: As per specification

Probe Type

Refer to application section before deciding on your probe

Rod Probes:

PP: Part-PTFE insulated Rod Probe

FP:Full PTFE insulated Rod Probe

CP:Part Ceramic insulated Rod Probe

Rope Probes:

RP10: Part-PTFE insulated Rope probe, SS rope with 10 mm thickness

RF10: Full PTFE insulated GI Rope probe with 10mm thickness

Extension Length

Pipe – GI/SS: 200mm – 3000mm

Wetted Parts

S4: SS-304

S6: SS-316

PTFE

Process Temperature

A (Ambient): below 100°C

H1 (High temperature): 100°C – 150°C (Stand-off – 100mm)

H2 (High temperature): 150°C – 250°C

H3 (High temperature): up to 650°C

Input power supply & Outputs

D: Universal Power Supply 18-55 V DC, 90-265 V AC, Single-point two potential free relay outputs rated at 6A

S: Universal Universal Power Supply 24-30 V DC, 90-265 V AC

(1.) Singe-point – Single relay (Rated 6A)

(2.) Open-collector PNP output, max 100mA non-inductive load

M: 24VDC – 8/16 mA 2-wire Loop powered current output

N: 8.2V Namur type current output (ION = 2.2 … 2.5 mA, IOFF = 0.8 … 1.0 mA) Namur compliance can be attained with a Namur certified isolator

Power Consumption

Maximum 4.8W at 24 V DC with PNP load at 90mA

Fail-safe Setting

Field selectable (through toggle switch)

Open: Fail-safe High, Close: Fail-safe Low

Response Time

Depends on the application material. e.g. for dry sand, response times are:

1s Cover Delay

1s Uncover Delay

Time Delay Settings

Cover and Uncover Delay: 0.8s / 1s to 20s, through toggle switches

Sensitivity Setting

5 Point sensitivity setting

Field Selectable (through toggle switches)

Applications Specifications

Coat-Endure is suitable for wide variety of powders, solids, pastes, slurries and liquids where Dielectric Constant(Er) > 1.4

For service temperature of more than 250 °C, Part Ceramic insulation is recommended

Note: Coat-Endure probes are application specific, for some applications it might be necessary to use a certain kind of probe. Please refer to the table before ordering your instrument, in case there is a doubt please contact our application engineers to study your application

Switching Indication

2 LED’s

Red: Alarm, Green: Normal